CharacteristicStandardSpecial case
MaterialKeyence AR-M2, Keyence AR-H1, FR2, PA12, PLA, ABS or PCAluminum, steel, PA12, ASA, PEEK, PEI, ceramic, or acrylic resin
Temperature resistance50 °C, 90 °C or 120 °CHigh-performance plastic: >200°C
In extreme cases, the test adapters can be made from ceramic or metal.
Hardness76 (Shore D, test method: durometer)
ESD protectionguaranteed by special coating
Contact resistance< 50 mΩ< 4 mΩ
Current1 amp> 100 amps
High frequencyNo special precautionsSpecial coaxial test pins, leads and connectors
Service life> 100.000 Cycles
(In practice often much more)
Design according to your requirements
Pitch≥ 1,27 mm≥ 0,5 mm (requires close examination)
ConformityCE (RoHS, REACH)